Key facts

  • 700/800/850/900/1800/1900/2100/2600 MHz BPFC UL bandpass filters
  • Rejection: ≥ 20 dB in specified frequencies
  • Return loss: ≥ 15 dB
  • Insertion loss: ≤ 1.5 dB
  • Continuous average power: ≤ 1 W (peak: ≤ 10 W)

Ideal for interference hunting

High-power signals transmitted by base stations might saturate the test equipment. The CCI bandpass filters eliminate this effect by blocking unwanted signals outside of the frequency range of interest and enabling a clear visualization of the signals present in the uplink range.

The bandpass filters consist of multiple cavity resonators to provide optimal performance for the passband with low insertion loss, low intermodulation and high power handling. The small form factor and low weight make the filters ideal for measurements in the field. 

Features & benefits

Focus on the signal you are looking for

Uplink signals are more susceptible to interference. During measurements performed close to a base station, high power downlink signals may interfere in the uplink frequency range.

A bandpass filter keeps the influence of downlink signals away, allowing you to analyze the uplink frequency range and spot the presence of interferers more easily and quickly.

Measurement results from a 900 MHz GSM network
Open Lightbox

Measurement results from a 900 MHz GSM network

The bandpass filter eliminates the influence of BTS signals and enables the easy identification of an interferer in the network.

Optimal performance

The BPFC bandpass filter from CCI provides optimal performance for the passband with low insertion loss and low intermodulation. Excellent return loss delivers the best match to the antennas and base station.

The bandpass filter consists of multiple cavity resonators to achieve 20 dB of rejection within the specified frequencies. Extensive temperature compensation is employed to insure frequency stability over the specified temperature range.

 BPFC bandpass filters
Open Lightbox

BPFC bandpass filters

Available models

Available models
Models
Rejection ≥ 20 dB
Start frequency (MHz)
Stop frequency (MHz)
Rejection ≥ 20 dB)

BPFC-0700

Rejection ≥ 20 dB
693
Start frequency (MHz)
703
Stop frequency (MHz)
748
Rejection ≥ 20 dB)
758

BPFC-0800

Rejection ≥ 20 dB
822
Start frequency (MHz)
832
Stop frequency (MHz)
862
Rejection ≥ 20 dB)
872

BPFC-0850

Rejection ≥ 20 dB
795
Start frequency (MHz)
815
Stop frequency (MHz)
850
Rejection ≥ 20 dB)
870

BPFC-0850X

Rejection ≥ 20 dB
805
Start frequency (MHz)
814
Stop frequency (MHz)
850
Rejection ≥ 20 dB)
859

BPFC-0900

Rejection ≥ 20 dB
870
Start frequency (MHz)
880
Stop frequency (MHz)
915
Rejection ≥ 20 dB)
925

BPFC-1800

Rejection ≥ 20 dB
1690
Start frequency (MHz)
1710
Stop frequency (MHz)
1785
Rejection ≥ 20 dB)
1805

BPFC-1900

Rejection ≥ 20 dB
1830
Start frequency (MHz)
1850
Stop frequency (MHz)
1910
Rejection ≥ 20 dB)
1930

BPFC-2100

Rejection ≥ 20 dB
1905
Start frequency (MHz)
1920
Stop frequency (MHz)
1980
Rejection ≥ 20 dB)
1995

BPFC-2600

Rejection ≥ 20 dB
2450
Start frequency (MHz)
2500
Stop frequency (MHz)
2570
Rejection ≥ 20 dB)
2620

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.