Deembedding oscilloscope software

General analysis

Deembedding oscilloscope software
Open Lightbox
Deembedding oscilloscope software
Open Lightbox
Deembedding oscilloscope software
Open Lightbox
Deembedding oscilloscope software
Open Lightbox
Deembedding oscilloscope software, Software Deembedding oscilloscope software, Screenshot Deembedding oscilloscope software, Screenshot Deembedding in realtime for fast results

Key facts

  • Deembedding in realtime for fast results
  • Correction of cascaded signal paths
  • Triggering on corrected signals
  • Full bandwidth for all trigger types

Deembedding in realtime for fast results

The realtime deembedding of signal path characteristics is based on S-parameters. Users benefit from highest acquisition speed even with activated realtime deembedding and precise triggering on compensated signal events up to the full instrument bandwidth.

Features & benefits

Deembedding in realtime for fast results

Traditional deembedding capabilities are extended with flexible filter structures directly after the A/D converters. This allows waveform correction in realtime. The advantages over deembedding the acquired waveform during postprocessing are the measurement speed and instrument responsiveness. In addition, triggering on corrected waveforms is possible.

Realtime deembedding architecture
Open Lightbox

Realtime deembedding architecture

The pictures shows how the signal shape changes over a lossy signal path. With realtime deembedding the original signal can be reconstructed.

Correction of cascaded signal paths

A cascade of signal path blocks can be defined for deembedding. The individual blocks are described by S-parameters that can be derived from simulation or measured with a vector network analyzer. The deembedding software automatically calculates the correction filter for the overall system response.

Menu to build up the signal path
Open Lightbox

Menu to build up the signal path

The signal path can be described easily by graphically adding up blocks. Each block can be descibed by S-parameters.

Triggering on corrected signals

Users can trigger on corrected waveforms and focus on debugging the true device characteristics. The unique digital trigger system operates with the sampling points of the A/D converter and the realtime deembedding filters. The trigger evaluates the real device signal since the distortion effects of the measurement path have been removed.

Correction of different cable length
Open Lightbox

Correction of different cable length

A diff. signal is measured using a 20cm and a 2m cable, resulting in different rise-time and skew. Deembedding ON corrects losses, rise-time and skew.

Full bandwidth for all trigger types

In addition to the edge trigger, advanced trigger types such as pulse width, runt and setup & hold work up to the full bandwidth of the R&S®RTP. This enables fast isolation of high-frequency signal components. The trigger sensitivity is adjustable from 0 to 5 div and the trigger resolution can be extended up to 16-bit with the high definition mode. Users can reliably trigger on even the smallest signal details.

Stable trigger on pulse width <= 50ps
Open Lightbox

Stable trigger on pulse width <= 50ps

Stable trigger on a signal overshoot with pulse width of less than 50 ps

Available models

Available models
Models
Correction in realtime
Trigger on corrected signals
RT-ZM probe compensation
Base unit

R&S®RTP-K121

Order number 1326.3064.02

Correction in realtime
Trigger on corrected signals
RT-ZM probe compensation
Base unit

R&S®RTP-K122

Order number 1326.3070.02

Correction in realtime
Trigger on corrected signals
RT-ZM probe compensation
Base unit

R&S®RTO-K121

Order number 1326.3058.02

Correction in realtime
Trigger on corrected signals
RT-ZM probe compensation
Base unit

R&S®RTO6-K121

Order number 1801.6887.02

Correction in realtime
Trigger on corrected signals
RT-ZM probe compensation
Base unit

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.