R&S®ESW-B1000 Wideband extension

Wideband extension for the highest testing speeds and greatest insight

R&S®ESW-B1000 Wideband extension
Open Lightbox
R&S®ESW-B1000 Wideband extension
Open Lightbox
R&S®ESW-B1000 wideband extension, application image R&S®ESW-B1000 wideband extension

Key facts

  • Up to 970 MHz FFT bandwidth for highest testing speeds
  • CISPR band C and D (30 MHz to 1 GHz) measured in one segment
  • More reliability for intermittent inference with longer measurement times
  • Real-time measurements without time gaps
  • Retrofittable hardware option for the  R&S®ESW EMI test receiver

Highest speed and greatest insight for EMI testing

The R&S®ESW-B1000 and R&S®ESW-B350 wideband options extend the R&S®ESW EMI test receiver FFT bandwidth to 970 MHz. The R&S®ESW can perform measurements in real-time with no gaps between consecutive measurements in the receiver spectrogram. CISPR bands C and D can be measured in a single shot or up to 450 MHz of real-time measurements in the frequency range above 1 GHz are possible for unprecedented testing speed and interference insight.

Features & benefits

Up to 970 MHz FFT bandwidth

The bandwidth extension option can speed up measurements with an FFT bandwidth of up to 970 MHz. With just one frequency segment to cover CISPR bands C and D, measurements are faster, even with CISPR detectors. Without scanning across frequency spans, the R&S®ESW can perform continuous, gap-free measurements, making it a real-time receiver. This helps when analyzing intermittent inference in the spectrogram view.

Measurement from 30 MHz to 1 GHz in one shot
Open Lightbox

Measurement from 30 MHz to 1 GHz in one shot

CISPR bands C and D are measured in one FFT segment with enabled CISPR detectors and a spectrogram view.

More insight into sporadic interference

With less receiver scanning, users will have more time for observations, while still achieving fast testing times. This increases likelihood that sporadic interference is intercepted and higher detection rates for high reliability and repeatability in both commercial and MIL-STD testing.

More interference insight
Open Lightbox

More interference insight

The wide bandwidth allows for long measurement times and the best insight into intermittent interference.

Real-time analysis

The wideband option measures in real-time without any time gaps between consecutive measurements. It detects sporadic or fast changing disturbances for detailed analysis. While remaining at a fixed frequency segment, the receiver can capture signals for a practically infinite amount of time without any time gaps.

Real-time measurement of a microwave oven
Open Lightbox

Real-time measurement of a microwave oven

Real-time FFT bandwidth of 450 MHz in the range above 1 GHz to analyze microwave out-of-band interference.

High dynamic range wideband testing

The wideband extension adds eight parallel paths to the input stage. Each path covers one frequency segment and when all are combined, the FFT bandwidth can be extended up to 970 MHz. Each path has its own preselection filter for frequency selectivity and a high dynamic range. An FPGA with high computing power combines the data streams from eight analog-to-digital converters and calculates the spectral components.

Wideband extension signal path
Open Lightbox

Wideband extension signal path

Eight parallel signal paths and a computational unit capture and process the wide real-time FFT bandwidth.

Wideband option concept

The wideband extension is available for the full FFT bandwidth of up to 970 MHz (R&S®ESW‑B1000) and 350 MHz (R&S®ESW‑B350). R&S®ESW‑B350 can be upgraded to R&S®ESW‑B1000 with a software license. Two versions are available for either option, the R&S®ESW‑B350/B350R or the R&S®ESW‑B1000/B1000R. The “non‑R” versions do not require export licenses, but are restricted to a real-time bandwidth of 170 MHz. The “R” version is export restricted and allows real-time processing of the full bandwidth.

Existing facelift instruments are upgradeable
Open Lightbox

Existing facelift instruments are upgradeable

If the ESW serial number is ≥ 103000, the R&S service center can retrofit the wideband option to an existing instrument.

Available models

Available models
Models
Max. FFT bandwidth (30 MHz ≤ f < 1000 MHz)
Max. FFT bandwidth (1 GHz ≤ f < 8 GHz)
Max. real-time bandwidth
Export license free

R&S®ESW-B350

Order number 1345.0438.02

Max. FFT bandwidth (30 MHz ≤ f < 1000 MHz)
350 MHz
Max. FFT bandwidth (1 GHz ≤ f < 8 GHz)
350 MHz
Max. real-time bandwidth
170 MHz
Export license free

R&S®ESW-B350R

Order number 1351.1184.02

Max. FFT bandwidth (30 MHz ≤ f < 1000 MHz)
350 MHz
Max. FFT bandwidth (1 GHz ≤ f < 8 GHz)
350 MHz
Max. real-time bandwidth
350 MHz
Export license free

R&S®ESW-B1000

Order number 1345.0421.02

Max. FFT bandwidth (30 MHz ≤ f < 1000 MHz)
970 MHz
Max. FFT bandwidth (1 GHz ≤ f < 8 GHz)
450 MHz
Max. real-time bandwidth
170 MHz
Export license free

R&S®ESW-B1000R

Order number 1351.1178.02

Max. FFT bandwidth (30 MHz ≤ f < 1000 MHz)
970 MHz
Max. FFT bandwidth (1 GHz ≤ f < 8 GHz)
450 MHz
Max. real-time bandwidth
970 MHz
Export license free
Specifications
FFT Bandwidth
TDS optimization: maximum speed, any detector, with R&S®ESW-B350/B350R option 30 MHz ≤ f < 8 GHz
RBW = 9 kHz 90 MHz
RBW = 120 kHz, 1 MHz 350 MHz
TDS optimization: maximum speed, any detector,
with R&S®ESW-B1000/B1000R option
30 MHz ≤ f < 1000 MHz
RBW = 9 kHz 90 MHz
RBW = 120 kHz 970 MHz
RBW = 1 MHz 880 MHz
1 GHz ≤ f < 8 GHz
RBW = 9 kHz 90 MHz
RBW = 120 kHz, 1 MHz 450 MHz
Receiver mode total measurement times
30 MHz to 1 GHz (CISPR band C/D) R&S®ESW-B1000/B1000R, 9 kHz RBW, 1 s MT, quasi-peak and CAV 22.5 s
R&S®ESW-B1000/B1000R, 120 kHz, 1 s MT, quasi-peak and CAV 1.8 s
1 GHz to 6 GHz (CISPR band E) R&S®ESW-B1000/B1000R, 1 MHz RBW, 1 s MT, peak and CAV 26 s
Promo: What's next? Taking industry leadership or watching from the sidelines?

What's next? Taking industry leadership or watching from the sidelines?

Take the lead with up to 60% off our devices!

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.