Key facts

  • The R&S®NGE102B with two or the R&S®NGE103B with three individual channels
  • Max. output power of 66 W with the R&S®NGE102B, 100 W with the R&S®NGE103B
  • Max. output voltage of 32 V per channel
  • USB interface (VCP/TMC), optional LAN (LXI), optional digital I/O (4bit)
  • Intuitive, price-transparent online product configurator

Starting at USD 1,210

Reduced to the max

The R&S®NGE100B DC power supply series consists of robust, high-performance, affordable instruments. They combine high efficiency with low ripple and a variety of comfort functions not usually found in this class of DC power supply.
The R&S®NGE100B is ideal for:
-R&D;
-Education
-Manufacturing tests
-Maintenance and repair
You can now easily configure the R&S®NGE100B DC power supply online. Benefit from full price transparency, the user-friendly configurator and fast purchase request processing with the authorized distribution partner of your choice. Click "Configure and quote" to start configuration. 

Features & benefits

All channels galvanically isolated and earth free

The circuitry in each channel is completely separated from the others with no connection to chassis ground. This makes combining the channels to drive bipolar circuitries that might need +12 V/–12 V easy and eliminates any ground problems in a complex DUT.

Driving a bipolar circuit
Open Lightbox

Driving a bipolar circuit

Combine channels to drive bipolar circuitry in complex DUTs that might need +12 V and –12 V without ground problems.

Parallel and serial operation

Because all channels are electrically equivalent, they can be combined in serial mode for higher voltages. Up to 96 V are possible with the R&S®NGE103B, up to 64 V with the R&S®NGE102B. Channels can be bundled for higher current in parallel mode. Up to 6 A are possible when two channels are combined. Using all three of the R&S®NGE103B channels, even 9 A is possible.

Parallel and serial operation
Open Lightbox

Parallel and serial operation

The output channels can be combined in serial or parallel for higher voltages or currents.

Protection functions

For each channel, users can separately set:

  • Maximum current (electronic fuse, overcurrent protection, OCP)
  • Maximum voltage (overvoltage protection, OVP)
  • Maximum power (overpower protection, OPP)
When a limit is reached, the output channel will automatically switch off and a message displayed. The overcurrent protection can be linked to other channels (FuseLink function). Here, the channel that exceeds the maximum current level and all linked channels are switched off.

Protection functions
Open Lightbox

Protection functions

If a limit is reached, the output channel will automatically switch off and a message will be displayed.

Color-coded operating conditions

All operating conditions are shown clearly on the 3.5" QVGA display (320 × 240 pixel), including the output power and the status of any protective functions. Colors indicate different operating conditions:

  • Active output is green when working in constant voltage mode and red when working in constant current mode
  • Inactive output is white. Whenever a channel is in setting mode, the number being set has a blue background.

The operating conditions are marked by colors
Open Lightbox

The operating conditions are marked by colors

Constant voltage is green, constant current red, inactive channels are white and a blue background indicates a channel in setting mode.

Connectivity

  • Front connectors with 4 mm safety binding posts
  • USB interface (virtual COM port and TMC class)
  • LAN interface (LXI) with integrated web server (R&S®NGE-K101 option) 
  • Wireless LAN, unique in class (R&S®NGE-K102 option)
  • Digital trigger in/out (4-bit) on the rear (R&S®NGE-K103 option)

Digital I/O
Open Lightbox

Digital I/O

Channel 1 of the optional digital I/O interface is used as a trigger input.

Easy to use, price transparent configurator

We help customers choose the right T&M instrument quickly, easily and with full price transparency. The R&S®NGP800 and other instruments from the R&S Essentials portfolio can now be configured online for the following benefits:
- User-friendly and easy to navigate configurator
- Full cost transparency at every step of configuration
- Fast order processing through authorized distribution partners 
- Next-day delivery from selected partners

Available models

Available models
Models
Number of output channels
Max. output power
Output voltage per channel
Output current per channel
Starting at

R&S®NGE102B

Order number 5601.3800.02

Number of output channels
2
Max. output power
66 W
Output voltage per channel
0 V to 32 V
Output current per channel
0 A to 3 A
Starting at
USD 1,210

R&S®NGE103B

Order number 5601.3800.03

Number of output channels
3
Max. output power
100 W
Output voltage per channel
0 V to 32 V
Output current per channel
0 A to 3 A
Starting at
USD 1,430
Specifications
Electrical specifications
Number of output channels 2/3
Total output power max. 66 W/100 W
Maximum output power per channel 33,6 W
Output voltage per channel 0 V to 32 V
Maximum output current per channel 3 A
Voltage ripple and noise (20 Hz to 20 MHz) typ. < 1.5 mV (RMS)
< 20 mV (peak-to-peak) (meas.)
Current ripple and noise (20 Hz to 20 MHz) < 2 mA (RMS) (meas.)
Load recovery time (10 % to 90 % load change within a band of ± 20 mV of set voltage) < 200 µs (meas.)
Programming/readback resolution voltage 10 mV
Programming/readback resolution current 1 mA
Output measurements
Readback resolution voltage 10 mV
Readback resolution current 1 mA
Readback accuracy voltage ±(% of output + offset) < 0.1 % + 20 mV
Readback accuracy current ±(% of output + offset) < 0.1 % + 5 mA
Special functions
Measurement functions voltage, current, power, energy
Protection functions OVP, OCP, OPP, OTP
FuseLink function
Fuse delay at output-on
Sense function -
Sink mode -
Output sequencing -
Trigger input/output -
Arbitrary function ● (EasyArb)
Analog/modulation interface -
Data logging -
Display and interfaces
Display 3.5" QVGA
Rear panel connections -
Remote control interfaces: standard USB
Remote control interfaces: optional LAN
General data
Dimensions (W × H × D) 222 mm × 97 mm × 310 mm
Weight 4.9 kg/5.0 kg
Rack installation R&S®HZC95 option

Available options

General analysis
Product
Description
R&S®NGE-K101

Order number 5601.2204.03

Description

Ethernet Remote Control

R&S®NGE-K103

Order number 5601.2227.03

Description

Digital Trigger I/O

General accessories
Product
Description
R&S®HZC95

Order number 5800.2054.02

Description

19" rack adapter, 2HU, for R&S®NGE100B/NGC100/NPA and R&S®HMC series

Further information

DC Power supplies & Power analyzer promotion

Save more than 19% on fully equipped power analyzer, DC power supplies and power meter from Rohde & Schwarz.

More information

Flyer: Power supplies. Versatile and compact.

Unique features for better results. Different power supply classes. Connectivity – everything you need.

Download now

Teaching-Software for Multi-User Student Labs

The R&S®CDS campus dashboard software simplifies teaching of student groups in laboratories with multiple workbenches.

Product information

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.