Key facts

  • Ultra-broadband frequency range: 2 GHz - 20 GHz
  • Output power: 20 W Psat and higher
  • High gain with low noise <8 dB and excellent linearity
  • Very suitable for AM, FM, PM, PhiM, OFDM
  • Compact, modular and robust for DVT / PVT and EMC
  • 3-year warranty extension

The perfect combination of high performance, wide bandwidth and low noise

The R&S®SAM100 system amplifier is an ultra-broadband solid state microwave amplifier with a frequency range from 2 GHz to 20 GHz. With a power of up to 20 W, outstanding linearity and very good noise characteristics, the R&S®SAM100 amplifier is ideal as a compact system amplifier in various measurement setups e.g. design (DVT) and product validation test (PVT) or EMC. In measurement environments with R&S generators, frequency analyzers or network analyzers, they can act as drivers or boosters and amplify the measurement signals. The R&S®SAM100 is also an excellent alternative to tube amplifiers as well as for multi-band assemblies consisting of narrow-band single amplifiers.

Features & benefits

Broadband amplification

Robust state-of-the-art solid-state technology for low-noise amplification

Ultra-Light and very compact 20 W microwave amplifier with the highest power density and a very low noise power density of << –100 dBm (1 Hz) at a bandwidth of one decade from 2 GHz – 20 GHz realized with the latest GaN-HEMT technology and a sophisticated thermal design using the heat pipe technology offers the user the possibility to amplify test signals for the design, testing and validation of RF components and devices.

R&S®SAM100 RF output power & noise figure
Open Lightbox

R&S®SAM100 RF output power & noise figure

Compact and modular

Flexible in use

With their modular, compact design, the R&S®SAM100 amplifiers can be used excellently in 19” system racks and PXI frames. They are also available as mobile desktop devices. In particular, their digital control interface predestines these amplifiers for integration into automatic test systems (ATE Systems). Its patented plug-in system for the microwave input and output plugs allows a choice between 2.92 mm or 3.5 mm plugs.

Up to 3x R&S®SAM100 in a 19“ rack frame for easy integration in Automated Test Systems (ATE)
Open Lightbox

Up to 3x R&S®SAM100 in a 19“ rack frame for easy integration in Automated Test Systems (ATE)

Available models

Available models
Models
Frequency range
Output power Psat

R&S®SAM100-0220-20

Order number 5358.9005K50

Frequency range
2 GHz - 20 GHz
Output power Psat
20 W

Available options

General
Product
Description
R&S®ZR-SAM-D

Order number 5358.2930.02

Description

Mounting kit desktop case

R&S®ZR-SAM-R

Order number 5358.2923.02

Description

Frame mounting kit

R&S®ZR-SAM-F

Order number 5358.2917.02

Description

19" frame for up to 3 × R&S®SAM100

R&S®SAM-B102

Order number 5358.2900.02

Description

Adapter 2,92 mm

R&S®SAM-B103

Order number 5358.2900.03

Description

Adapter 3,5 mm

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.