How to measure O-RU performance
For transmitter tests, predefined O-RAN/3GPP test cases or user-specific FDD/TDD waveforms can be generated with the signal generator and loaded on the O-RU tester with the U-plane format. After initial O-RU configuration via the M-plane, the O-RU tester sends the C-plane and U-plane information along with S-plane data to the O-RU, which processes the data and transmits the RF signal. The Rohde & Schwarz signal and spectrum analyzer captures and demodulates the signal.
The transmitted RF signal can be selected from the signal generator for receiver tests. The O-RU processes the captured signal and sends it to the O-RU tester via an Ethernet link following O-RAN split 7-2x.
The VIAVI O-RU Test Manager Application provides a clear pass/fail report for the test results. Users can run the R&S®VSE vector signal explorer software to analyze signals in further detail for in-depth debugging.
In contrast to O-RU conformance testing, full 3GPP base station conformance testing requires a pairwise setup with an O-RU and O-DU. The O-RU test solution provides 3GPP base station pre-conformance testing for an O-RU in isolation.