Arbitrary waveform generator oscilloscopes

Arbitrary waveform generator oscilloscopes
Open Lightbox
Arbitrary waveform generator oscilloscopes
Open Lightbox
Arbitrary waveform generator oscilloscopes
Open Lightbox
Arbitrary waveform generator oscilloscopes, Screenshot Arbitrary waveform generator oscilloscopes, Application Image Arbitrary waveform generator oscilloscopes, Back view

Key facts

  • Every R&S®RTP, R&S®RTO2000 and R&S®RTE can be enhanced to include an arbitrary waveform generator
  • Test your device with native signals
  • Single-ended and differential interface stimulation
  • Fully automated compliance tests with the R&S®B6 option
  • Multi-domain icon

Brief description

Arbitrary waveform and pattern generator with 14-bit resolution, 2 analog channels, 8 digital channels, 100 MHz bandwidth, 40 Msample/channel memory, 500 Msample/s sampling rate. Waveforms and patterns can be imported as CSV files or copied from oscilloscope waveforms. Before playing signals back, the user can preview them to quickly check signal correctness.

Features & benefits

Enhancement for R&S®RTP, R&S®RTO2000 and R&S®RTE oscilloscopes

The R&S®RTP, R&S®RTO2000 and R&S®RTE oscilloscopes can be enhanced with a fully integrated arbitrary waveform and pattern generator. The generator provides 2 analog and 8 digital channels with up to 100 MHz bandwidth, 500 Msample/s and 14-bit resolution and can be operated as a pattern, function or modulation generator. It is suitable for education, design and R&D purposes.

Open Lightbox

Single-ended and differential interface stimulation

For testing differential devices, the generators can be coupled and offset from each other. With the offset capability of amplitude and phase in coupled mode, you can simulate both ideal and non-ideal conditions. Differential devices, such as differential amplifiers or I/Q mixers, can be tested against amplitude impairments and phase imbalances.

Open Lightbox

Test your device with native signals

Testing your device with real-world signals opens up a new method to test the margins of your design. The arbitrary waveform generator lets you play back waveforms that are captured on the oscilloscope. The captured waveforms can be manipulated by changing the amplitude and offset level or be superimposed with noise to evaluate a device against design criteria.

Open Lightbox

Fully automated compliance tests

Compliance tests can be fully automated utilizing the B6 arbitrary waveform generator, eliminating the need for an external signal source. R&S®ScopeSuite is able to control the waveform generator and provide, for instance, the disturbing signal needed for Ethernet compliance testing. As a result, the R&S®RTO and R&S®RTP offer the most compact compliance test solutions on the market.

Open Lightbox

Available models

Available models
Models
Analog channels
Digital channels
Bandwidth
Sample rate
Resolutions
Base unit

R&S®RTE-B6

Order number 1326.3012.02

Analog channels
2
Digital channels
8
Bandwidth
100 MHz
Sample rate
500 Msample/s
Resolutions
14 bit
Base unit

R&S®RTO-B6

Order number 1329.7054.02

Analog channels
2
Digital channels
8
Bandwidth
100 MHz
Sample rate
500 Msample/s
Resolutions
14 bit
Base unit

R&S®RTP-B6

Order number 1333.2418.02

Analog channels
2
Digital channels
8
Bandwidth
100 MHz
Sample rate
500 Msample/s
Resolutions
14 bit
Base unit

R&S®RTO6-B6

Order number 1801.6758.02

Analog channels
2
Digital channels
8
Bandwidth
100 MHz
Sample rate
500 MSample/s
Resolutions
14 bit
Base unit

R&S®MXO4-B6

Order number 1335.4147.02

Analog channels
2
Digital channels
-
Bandwidth
100 MHz
Sample rate
500 MSample/s
Resolutions
18 bit
Base unit

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.